ASME A112.14.6-2006 pdf free download.FOG (Fats, Oils,and Greases)Disposal Systems.
2.1.1 Design Performance. FOG disposal system designs and methods shall produce an effluent quality not In exccd IOU mg/I. FOG ax stated in para. 4.3.2.
2.1.2 Flow Rate. KX disposal systems shall be described by total gpm influent.
2.1.3 Inlet and Outlet Connections. The inlet and outlet connections of the FOG disposal system shall be either a female pipe thread or a plain end diameter to allow hubless coupling connections. Tapered threads shall comply with ASME BI .20.1. Hubless connections shall comply with the outside dimension for the given pipe size in accordance with ASTM A 888 or ASME A112.3.1.
2.2 Electrical
All electrical components used in the FOG disposal system shall conform to the appropriate sections of UI. Standards 499,917, 1004, and 15S5 as listed in para. 1.3.
2.3 Manufacture
2.3.1 FOG disposal systems shall be Iwe of manulacture and/or material defects that affect performance. or serviceability.
2.3.2 FOG disposal systems shall be designed to withstand anticipated installation and use asseciated F(x; loading.
2.3.3 Each FOG disposal system and cover designated for buried application shall he structurally designed to withstand earth or other loads pertinent to its location.
2.3.4 FOG disposal systems and covers for buried
applications in nonvehicular traffic areas shall be
designed for an earth load of not less than 500 psf
(24 kPa) when the m.is.inium coverage does not exceed
3 ft (0.9 m).
2.3.5 FOG disposal systems and covers for installation in traffic areas shall be designed to withstand an AASHT() H20-44 wheel load, an additional 3 ft (0.9 m) earth load with an assumed soil weight of l0() psf (4.tt kPa). and 30 psI (1.4 kPa) fluid equivalent sidewall pressure.
2.3.6 Internal construction shall be designed to withstand the maximum expected conditions that include, but are not limited to, chemical, thermal, electrostatic and hydrostatic pressure.
3 SPECIAL REQUIREMENTS
3.1 Separation/Retention Efficiency
Rx disposal systenvs shall have a minimum separation/retention efficiency in accordance with ASME Al 12.14.3 or PDI-G1O1,
3.2 Application Documentation
Each FOG disposal system shall be provided with complete application instructions including, but not timited to, the following:
a) flow control and/or vent requirements (1’) any separate trapping requirements
fc) elevation and accessibility requirements (dl safety and health-related structkwis
fr) wiring instructions to reference national or local codes
(f) clean-out locations
(gi tnstructions that show the clearances required fur maintenance, cleaning, and prevention of hazards
3.3 Maintenance and Operation Documentation
Each FOG disposal system shall be provided with maintenance and operation documentation, which include a troubleshooting guide as well as instructions for performing necessary servicing or obtaining outside servicing. Units shall be provided with complete maintenance and operating instructions.
3.4 InstallatIon
3.4.1 Installation shall be in accordance with the manufacturer’s recommendations and thc applicable plumbing codes.
3.4.2 Each unit shall be packaged with illustrated directions detailing correct installation procedures.
3.4.3 In buried applications of FOG disposal systems. access to each system shall be provided. There shall be access for each 10 ft (3-03 m) of length for FOG disposal systems over 21) It (6.1 m) long. Each access opening shall have a leak-resistant closure (i.e., lid) that cannot slide, rotate, or flip exposing the opening. and which does not require the use of mechanical fasteners and be of a vandal-resistant type.
3.4.4 Manholes, if applicable, shall extend to grade; have a minimum diameter size of 20 in. (510 mm) diame. tcr or 20 in. X 20 In, (510 mm X 510 mm); and shall be provided with a fitted, water-tight cover. Manholes shall be capable of withstanding all anticipated loads and comply with IAPMO PS-I, para. 4.7.1, which requires that all manholes have a leak-resistant closure that, when properly installed, cannot slide, rotate, or flip exposing the opening.. and which does not require the use of nwchanical fasteners.